[HIOKI PW6001] POWER ANALYZER / 전력계
HIOKI PW6001 POWER ANALYZER
주요특징 (Features)
• 전력 기본 확도 ±0.05% 실현 (전류 센서 확도를 가산하여도 ±0.075%)
• 높은 노이즈 내성과 높은 안전성 (80dB / 100kHz CMRR, ±0.01%/℃ 온도 특성)
• 변동이 큰 부하에도 정확한 측정을 실현, True HD 18bit
• 최고 확도를 유지하며 10ms의 데이터 갱신을 구현(전용 IC를 통한 독립/동시 측정)
• DC 기본 확도 ±0.07%, 정확하고 안정적인 효율 측정
• 정확한 주파수 해석을 실현한 고속 SAMPLING, 5MS/s
• 6CH 모델 2대의 real time 동기화로 최대 12ch구현
• 오실로스코프를 대체하는 충실한 파형해석, 모터 해석 전용의 TRIGGER기능
• 1.5MHz의 대역, 최대 100차까지 광대역 고조파 해석이 가능
▣ 모델사양
Model No. | 사양 설명 |
---|---|
PW6001-06 | 6ch |
PW6001-16 | 6ch, motor analysis, D/A output |
상세설명 (Description)
DC, 0.1 Hz to 2 MHz, 3-phase 4-wire, High Precision
Power Analyzer for Motor and Inverter Efficiency Analysis
Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW6001 is Hioki’s flagship power analyzer, featuring high accuracy, wide band, and high stability for measuring electrical power from DC to inverter frequencies, providing maximum of 12 channels* to support single- and three-phase inverter motor system measurements and next generation devices such as silicon-carbide (SiC) inverters.
* When synchronizing two 6-channel models connected via optical link
0.1 Hz to 2 MHz frequency bandwidth
Power measurements across wide bandwidths are required for supporting high-speed switching devices such as SiC. |
|
High-speed sampling of 5 MS/s for true frequency analysis
Power measurements across wide bandwidths are required for supporting high-speed switching devices such as SiC. |
|
Fast, simultaneous calculation functions achieved with Power Analysis Engine II
All measurements, including period detection, wideband power analysis, harmonic analysis, and waveform analysis, are digitally processed independently and with no effect on each other. Fast calculation processing is used to achieve a data update speed of 10 ms while maintaining maximum |
|
Strengthened resistance to noise and temperature fluctuations in the absolute pursuit of measurement stability
The custom-shaped solid shield made completely of finely finished metal and optical isolation devices used to maintain sufficient creepage distance from the input terminals dramatically improve noise resistance, provide optimal stability, and achieve a CMRR performance of 80 dB/100 kHz. Add the superior temperature characteristics of ±0.01%/°C and you now have access to a power analyzer that delivers top-of-the-line measurement stability. |
|
Analyze waveforms without an oscilloscope
In addition to voltage and current waveforms, torque sensor and encoder signals can also be displayed simultaneously. The PW6001 is also built in with triggers, pre-triggers, other triggers convenient for motor analysis such as for PWM waveforms, as well as encoder pulse triggers. |
|
Harmonic analysis up to 1.5 MHz
Wideband harmonic analysis is provided as a standard feature to a max. 100th order for fundamental frequencies 0.1 Hz to 300 kHz and an analysis band of 1.5 MHz. Analysis of fundamental waves in motors and measurement of distortion rate in the transmission waveforms for wireless power supplies |
|
FFT analysis of target waveforms
Frequency analysis up to 2 MHz. Specify any waveform analysis range you like and see the 10 highest peak values and frequencies displayed. |
|
Digital LPF for displaying the waveform you want to view
Select a cutoff frequency for the measurement target. Digital LPF greatly reduces noise to let you display the waveform you want to view. |
|
Seamless operability
Time spent on operations is reduced, to allow focused concentration on analysis. |
|
One-touch settings take you to measurement immediately
The built-in easy setup function allows you to simply select the type of measurement line and immediately start measurement using the automated optimum settings | |
DC accuracy is indispensable for achieving correct efficiency measurements
For example, when measuring the efficiency of a DC/AC converter, not only AC accuracy but also DC accuracy are equally important. With the PW6001, a DC measurement accuracy of ±0.02% rdg. ±0.05% f.s.* delivers correct and stable efficiency measurements. *Unit accuracy only |
|
Specially designed for current sensors to achieve highly precise measurement
|
|
High-accuracy clamp current sensor
The CT684x series feature broad temperature characteristics and an operating temperature range of -40°C to 85°C, allowing them to be used in operational evaluations of devices and inside equipment that are subject to extreme temperature changes. The current sensors’ tough performance helps ensure you can make the measurements you need. |
|
Get a combined accuracy of ±0.07% rdg. even with current sensor
*Effective measurement range. |
|
Wideband current probes supported
When combined with the HIOKI CT6700, it is also possible to measure minute currents of 1 mA. This is perfect for observing leakage current waveforms in inverters. |
|
PW9100, The optimal device for testing inverters
The newly developed DCCT method provides world-leading measurement bands and accuracy at a 50 A rating. Delivering a direct-coupled type current testing tool that brings out the PW6001 POWER ANALYZER's maximum potential. * For complete details, please refer to the specifications |
|
PC Communication Software – PW Communicator
PW Communicator is an dedicated application software for communicating between a PW6001 power meter and a PC. Free download is available from the Hioki website. The application contains convenient functions for setting the PW6001, monitoring the measurement values, acquiring data via communication, computing efficiency, and much more. |
|
Remote control via LAN
Control the PW6001 remotely from a tablet, smartphone, or any device offering a standard web browser. |
|
Diverse motor analysis functions
Enter signals from torque meters and speed meters to measure motor power. In addition to motor parameters such as motor power and electrical angle, output signals from insolation meters and wind speed meters can also be measured. |
|
SiC measurement achieved with high resolution
High resolution is required for the high precision measurement of PWM waveforms for SiC semiconductors with low ON resistance. TrueHD 18-bit is achieved at a level of precision that has never been seen before. |
|
Advanced electrical angle measurement function
The PW6001 features a built-in electric angle measurement function required for the measurement of motor parameters in high-efficiency synchronized motors and the analysis of vector control via dq coordinate systems. Make real-time measurements of phases for voltage and current fundamental wave components based on encoder pulses. Further, zero-adjustment of the phase angle when induced voltage occurs allows phase measurement at the induction voltage standard. Finally, the PW6001 can detect the forward/reverse from A phase and B phase pulses to enable 4-quadrant analysis of torque and RPM.
|
|
Display any calculation result in real-time
Set equations to have PW6001 compute measurement values in the way you want. You can enter up to 16 calculation formulas, and functions like sin and log are supported. Calculation results can be used as parameters for other calculation formulas, enabling complex analysis. |
|
Power conditioner testing
Parameters required for power conditioners, such as fundamental wave reactive power Qf nd, DC ripple rate, and 3-phase unbalanced rate, can be measured and displayed simultaneously. The required measurement data can be viewed at a glance, improving test efficiency. |
|
Build a 12-channel power meter using “numerical synchronization”
For multi-point measurements, use the numerical synchronization function to transfer power parameters from the slave device to aggregate at the master in real-time, essentially enabling you to build a 12-channel power analysis system |
|
Simply transfer waveforms with “waveform synchronization”
Achieve real-time* transfer of 5 MS/s 18-bit sampling data. Measurement waveforms on the slave instrument are displayed without modification on the master unit, paving the way for new applications for power analyzers, such as measurement of the voltage phase difference between two separate devices. * For both master instruments and slave instrument, waveform synchronization operates only when there are 3 or more channels. Max. ±5 sampling error
|
Technical specifications
Measurement line type | Single-phase/three-wire, three-phase/three-wire |
---|---|
Number of input channels | Voltage, Current, Current peak, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Power integration, Current integration |
Measurement items | Voltage (U), current (I), active power (P), apparent power (S), reactive power (Q), power factor (λ), phase angle (φ), frequency (f), efficiency (η), loss (Loss), voltage ripple factor (Urf), current ripple factor (Irf), current integration (Ih), power integration (WP), voltage peak (Upk), current peak (Ipk) |
Harmonic measurement: Harmonic active power, select calculation order from 2nd order to 100th order | |
Waveform recording: Voltage and current waveforms/ Motor pulse: Always 5 MS/s Motor waveforms: Always 50 kS/s, 16 bits Recording capacity: 1 Mword × ((voltage + current) × number of channels + motor waveforms) |
|
Motor analysis (PW6001-11 to -16 only): Voltage, Torque, Rotation, Frequency, Slip, or Motor output | |
Measurement range | Voltage range: 6 to 1500 V, 8 ranges Current range (Probe 1) : 400 mA to 1 kA (depends on current sensor) Current range (Probe 2) : 100 mA to 50 kA (depends on current sensor) Power range: 2.40000W to 4.50000MW (depends on combination of voltage and current range) Frequency range: 0.1 Hz to 2 MHz |
Basic accuracy | Voltage: ±0.02 % rdg. ±0.02 % f.s. Current: ±0.02 % rdg. ±0.02 % f.s. + current sensor accuracy Active power: ±0.02 % rdg. ±0.03 % f.s. + current sensor accuracy |
Synchronization frequency range | Power measurement: 0.1 Hz to 2 MHz Harmonic measurement: 45 Hz to 66 Hz (IEC standard mode), 0.1 Hz to 300 kHz (Wideband mode) |
Frequency band | DC, 0.1 Hz to 2 MHz |
Data update rate | Power measurement: 10 ms/ 50 ms/ 200 ms Harmonic measurement: 200 ms (IEC standard mode), 50 ms (Wideband mode) |
Data save interval | OFF, 10 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes User-selected from all measured values, including harmonic measured values, Specified measured values can be saved in internal memory or USB flash drive |
External interfaces | USB (memory), LAN, GP-IB, RS-232C, External control ,Synchronization control |
Power supply | 100 to 240 V AC, 50/60 Hz, 200 VA max |
Dimensions, mass | 430 mm (16.93 in)W × 177 mm (6.97 in)H × 450 mm (17.72 in)D, 14 kg (49.4 oz) (PW6001-16) |
Accessary
기본 악세사리 | |
---|---|
• Instruction Manual ×1 • Power cord ×1 • D-sub connector × 1 (PW6001-1x only) |
- 배송비 : 1,000,000원 이상 구매시 무료배송이며, 미만 주문시 5,000원의 택배비가 청구됩니다.
도서, 산간지방 및 일부지역은 배송비가 추가될 수 있습니다.(퀵, 다마스 배송은 별도 문의부탁드립니다)
- 배송기간 : 배송은 일반적으로 결제후 2~7일이 소요됩니다.(토요일/공휴일 제외, 도서지역 4~8일)
특수제품, 주문제작 및 직수입 상품의 경우 별도 배송일을 안내해 드립니다.
배송예절일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과 차이가 발생할 수 있습니다.
- 본 상품의 배송 가능일은 15일입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.
(단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)
교환/환불 |
환불 |
교환 |
단순변심 |
고객님 부담으로 환불금액에서 왕복 배송비가 차감되어 환불됩니다. |
왕복 배송비 확인 후 박스에 동봉해서 보내주세요. - 일반적으로 교환이나 환불시 10,000원의 왕복배송비가 적용됩니다.(상품에 따라 상이 할 수 있습니다) - 재고가 없는 경우 환불처리 될 수 있습니다. |
제품하자 및 오배송 |
판매자 부담이므로 상품만 보내주시면 됩니다. |
교환/환불이 불가능 한 경우 |
|
환불/교환 요청기간 초과 |
환불/교환 기간 이후 요청하는 경우(배송완료 시점으로부터 15일 초과시) 단, 수령한 상품이 표기 광고의 내용과 다르거나 계약 내용과 다르게 이행된 경우에는 수령한 날로부터 3개월 이내, |
재고가 부족한 경우 |
단순변심으로 교환을 요청했으나, 재고가 부족한 경우(환불 처리 될 수 있습니다) |
특수제품/ 주문제작/ 직수입제품 |
주문/제작 상품의 제작이 이미 진행된 경우, 직수입 제품의 경우 주문서가 들어간 경우 |
분실/ 파손/ 고장/ 오염 발생 | 상품택/ 구성품 분실 및 취급 부주의로 인한 파손/고장/오염 등이 발생한 경우 |
모니터 해상도 차이 | 모니터 해상도 차이로 인하여 색상 등 이미지가 실제와 상이한 경우 |
기타 불가사유 | ① 제품박스가 손상되거나 찢어진 경우 ② 고유팩 포장을 분리하거나 훼손하였을 경우 ③ 렌즈에 이물질 및 지문등의 흔적이 남은 경우 |
<기타 불가 사유 참고 이미지>
|
- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.
- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오.
- 상품 청약철회 가능기간은 상품 수령일로 부터 15일이내 입니다.
- 일부 특수 제품, 주문제작 및 직수입 제품의 경우 교환/반품이 어려울 수 있습니다.
- 구매전 충분히 상담하시고, 신중하게 구매 해 주시기 바랍니다.
- 저희 텍캄몰에서 구매하신 제품과 상품은 정품으로 본사 및 전문점에서 A/S를 받을 수 있습니다.
- 무상 A/S기간에 상관없이 밴드교체 및 유리교체 등 소모품성 및 고객님의 부주의로 인한 파손은 유상 A/S(비용청구)로 처리됩니다.
- A/S 처리방법은 매장으로 방문하시거나 전화해 주시고, 우편이나 택배이용시 배송료는 본인 부담입니다.
- A/S 처리기간은 고장상태와 부품조달 관계로 1주일에서 최장 3개월까지 걸릴 수 있습니다.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.