주요특징 (Features)
• Power Analysis for 3P4W, 3P3W, 1P2W, 1P3W
• True RMS value (V123 and I123)
• Active Power (W, KW, MW, GW)
• Apparent and Reactive Power (KVA, KVAR)
• Power Factor (PF), Phase Angle (Φ)
• Energy (WH, KWH, KVARH, PFH)
• AC Current (10A to 3000A) and Voltage measurement: True RMS, Auto Range.
• Capable of analyzing IT standby power consumption to the maximum demand of a factory
• Display of 35 Parameters in One Screen (3P4W)
• Programmable CT (1 to 600) and PT (1 to 3000) Ratios
• Display of Overlapped Voltage and Current Waveform
• Average Demand (AD in W, KW, MW)
• Maximum Demand (MD in KW, MW, KVA, MVA) with Programmable Period
• Harmonic Analysis to the 99th Order
• Display of 50 Harmonics in one Screen with Waveform
• Display of Waveform with Peak Values (1024 Samples / Period)
• Analysis of Total Harmonic Distortion (THD-F)
• Graphic Phasor Diagram with 3 Phase System Parameters
• Capture 28 Transient Events (Time + Cycles) with Programmable Threshold (%)
• DIP, SWELL, and OUTAGE are included in transient events.
• 3 Phase Voltage or Current Unbalance Ratio (VUR, IUR)
• 3 Phase Voltage or Current Unbalance Factor (d0%, d2%)
• Calculated Unbalanced Current through Neutral Line (In)
• 512K Memory with Programmable Interval (Sampling time from 2 to 3000 seconds, 17,000 records for 3P4W system)
• Output of Waveform, Power Parameters and Harmonics at Command
• Large Dot Matrix LCD Display with Backlight
• Software to work with PC via Optical Isolated RS-232C to USB Interface
• Built-in timer and calendar for data logging
Technical Specifications
Electrical Specifications: (23℃±5℃) | |||
AC Watt | |||
Range (0 to 3000A) | Resolution | Accuracy of Readings | |
---|---|---|---|
> 20 V and > 30A | < 20V or < 30A | ||
10.0 – 999.9 W | 0.1W | ±1% of range | ±2% of range |
1.000 – 9.9 | 0.001 KW | ||
10.00 – 99.99 KW | 0.01 KW | ||
100.0 – 999.9 KW | 0.1 KW | ||
1000 – 9999 KW | 1 KW | ||
Range of CT (Current Transformer) Ratio: 1 to 600 AC Apparent Power (VA, from 0.000 VA to 9999 KVA): VA = V r.m.s. x A r.m.s AC Reactive Power (VAR, from 0.000 VAR to 9999 KVAR): VAR = √(VA2 – W2) AC Active Energy (mWH, WH, or KWH, from 0mWH to 999,999KWH): WH = W * Time (in hours) |
|||
AC Current (Auto range, TRMS, Overload Protection AC 3000A) | |||
Range | Resolution | Accuracy of Readings | |
10.0 – 300.0A | 0.01A / 0.1A | ±1% of range | |
300.0 – 3000A | 0.1A / 1A | ||
AC Voltage (Auto range, TRMS, Overload Protection AC 800V) | |||
Range | Resolution | Accuracy of Readings | |
20.0 V – 500.0 V (Phase to Neutral) | 0.1 V | ±0.5% ± 5dgts | |
20.0 V – 600.0 V (Phase to Phase) | |||
Range of VT (Voltage Transformer) Ratio: 1 to 3000 | |||
Harmonics of AC Voltage in Percentage | |||
Range | Resolution | Accuracy | |
1 – 20th | 0.1% | ±2% | |
21 – 49th | ±4% of reading ± 2.0% | ||
50 – 99th | ±6% of reading ± 2.0% | ||
Harmonics of AC Voltage in Magnitude | |||
Range | Resolution | Accuracy | |
1 – 20th | 0.1V | ±2% ± 0.5V | |
21 – 49th | ±4% of reading ± 0.5V | ||
50 – 99th | ±6% of reading ± 0.5V | ||
Peak Value of ACV (peak value > 20V) or ACA (peak value > 30A), VT=1 | |||
Range | Resolution | Accuracy of Reading | |
50 Hz | 19μs | ± 5% ± 30 digits | |
60 Hz | 16μs | ||
Crest Factor (C.F.) of ACV (peak value >20V) or ACA (peak value > 30A), VT=1 | |||
Range | Resolution | Accuracy of Reading | |
1.00 – 99.99 | 0.01 | ± 5% ± 30 digits | |
Harmonics of AC Current in Percentage | |||
Range | Resolution | Accuracy | |
1 – 20th | 0.1% | ±2% | |
21 – 49th | ±6% | ||
50 – 99th | ±10% | ||
Harmonics of AC Current in Magnitude (1 to 99th order, min. current at the 50 or 60 Hz, True RMS < 300A) | |||
Range (0 – 300A) | Resolution | Accuracy | |
1 – 20th | 0.1% | ±2% of reading ± 4A | |
21 – 50th | ±4% of reading ± 4A | ||
51 – 99th | ±6% of reading ± 4A | ||
(1 to 99th order, min. current at the 50 or 60 Hz, 3000A > True RMS > 300A) | |||
Range (300 – 3000A) | Resolution | Accuracy | |
1 – 20th | 0.1% | ±2% of reading ± 40A | |
21 – 50th | ±4% of reading ± 40A | ||
51 – 99th | ±6% of reading ± 40A | ||
Power Factor (PF) | |||
Range | Resolution | Accuracy | |
> 20V and > 30A | < 20V or < 30A | ||
0.000 – 1.000 | 0.001 | ± 0.04 | ±0.1 |
Phase Angle (Φ, V > 20V, A > 30A) | |||
Range | Resolution | Accuracy | |
-180° to 180° | 0.1° | ± 2° | |
0° to 360° | |||
Frequency of ACV (RMS value > 10V) or ACA (RMS value > 30A) | |||
Range | Resolution | Accuracy | |
45 – 65 Hz | 0.1 Hz | ± 0.2Hz | |
Total Harmonic Distortion (THD-F) | |||
Range | Resolution | Accuracy | |
0.0 – 20% | 0.1% | ± 2% | |
20 – 100% | ± 6% of reading ± 5% | ||
100 – 999.9 % | ± 10% of reading ± 10% |
General Specifications: Indoors Use | |
PROVA 6830A Analyzer | |
Battery Type | 1.5V SUM-3 x 8 |
---|---|
External DC Input | Use only power supply adapter Model PHAPSA |
Display | Dot Matrix LCD (240x128) with backlight |
LCD Update Rate | 1 time / second |
Power Consumption | 140mA (approx.) |
No. Of Samples | 1024 samples / period |
Data Logging Files | 85 |
Max. File Capacity | 17474 records (3P4W, 3P3W) 26210 records (1P3W) 52420 records (1P2W) 4096 records (50 Harmonics / record) |
Sampling Time | 2 to 3000 seconds for data logging |
Overload Indication | OL |
Operating Temperature | -10°C to 50°C |
Operating Humidity | less than 85% relative |
Storage Temperature | -20°C to 60°C |
Storage Humidity | less than 75% relative |
Dimension | 257 (L) x 155 (W) x 57 (H) mm /10.1” (L) x 6.1” (W) x 2.3” (H) |
Weight | 1160g (Batteries included) |
AFLEX 3007 Flexible Current Probes | |
Probe Length: 3007-24 | 24 in / 610 mm |
Minimum Bending Diameter | 35mm |
Connector Diameter | 23mm |
Cable Diameter | 14mm |
Cable Length from Probe to Box | 1700mm |
Cable Length from Box to Output | 1700mm |
Range Selection | Manual (300A, 3000A) |
Battery | powered by power analyzer |
Dimension (Box) | 130mm(L) x 80mm(W)x 43mm(H) / 5.1”(L) x 3.1”(W) x 1.7”(H) |
Weight | 410g |
Accessary
기본 악세사리 |
---|
• Probes (model 3007) x 3 • Test leads (3 meter long) x 4 • Alligator clips x 4 • Carrying bag • Users manual • Batteries 1.5V x 8 • AC power adapter • Software CD • Software users manual • USB to RS232 cable |
- 배송비 : 1,000,000원 이상 구매시 무료배송이며, 미만 주문시 5,000원의 택배비가 청구됩니다.
도서, 산간지방 및 일부지역은 배송비가 추가될 수 있습니다.(퀵, 다마스 배송은 별도 문의부탁드립니다)
- 배송기간 : 배송은 일반적으로 결제후 2~7일이 소요됩니다.(토요일/공휴일 제외, 도서지역 4~8일)
특수제품, 주문제작 및 직수입 상품의 경우 별도 배송일을 안내해 드립니다.
배송예절일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과 차이가 발생할 수 있습니다.
- 본 상품의 배송 가능일은 15일입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.
(단, 연휴 및 공휴일은 기간 계산시 제외하며 현금 주문일 경우 입금일 기준 입니다.)
교환/환불 |
환불 |
교환 |
단순변심 |
고객님 부담으로 환불금액에서 왕복 배송비가 차감되어 환불됩니다. |
왕복 배송비 확인 후 박스에 동봉해서 보내주세요. - 일반적으로 교환이나 환불시 10,000원의 왕복배송비가 적용됩니다.(상품에 따라 상이 할 수 있습니다) - 재고가 없는 경우 환불처리 될 수 있습니다. |
제품하자 및 오배송 |
판매자 부담이므로 상품만 보내주시면 됩니다. |
교환/환불이 불가능 한 경우 |
|
환불/교환 요청기간 초과 |
환불/교환 기간 이후 요청하는 경우(배송완료 시점으로부터 15일 초과시) 단, 수령한 상품이 표기 광고의 내용과 다르거나 계약 내용과 다르게 이행된 경우에는 수령한 날로부터 3개월 이내, |
재고가 부족한 경우 |
단순변심으로 교환을 요청했으나, 재고가 부족한 경우(환불 처리 될 수 있습니다) |
특수제품/ 주문제작/ 직수입제품 |
주문/제작 상품의 제작이 이미 진행된 경우, 직수입 제품의 경우 주문서가 들어간 경우 |
분실/ 파손/ 고장/ 오염 발생 | 상품택/ 구성품 분실 및 취급 부주의로 인한 파손/고장/오염 등이 발생한 경우 |
모니터 해상도 차이 | 모니터 해상도 차이로 인하여 색상 등 이미지가 실제와 상이한 경우 |
기타 불가사유 | ① 제품박스가 손상되거나 찢어진 경우 ② 고유팩 포장을 분리하거나 훼손하였을 경우 ③ 렌즈에 이물질 및 지문등의 흔적이 남은 경우 |
<기타 불가 사유 참고 이미지>
|
- 상품 택(tag)제거 또는 개봉으로 상품 가치 훼손 시에는 상품수령후 7일 이내라도 교환 및 반품이 불가능합니다.
- 일부 특가 상품의 경우, 인수 후에는 제품 하자나 오배송의 경우를 제외한 고객님의 단순변심에 의한 교환, 반품이 불가능할 수 있사오니, 각 상품의 상품상세정보를 꼭 참조하십시오.
- 상품 청약철회 가능기간은 상품 수령일로 부터 15일이내 입니다.
- 일부 특수 제품, 주문제작 및 직수입 제품의 경우 교환/반품이 어려울 수 있습니다.
- 구매전 충분히 상담하시고, 신중하게 구매 해 주시기 바랍니다.
- 저희 텍캄몰에서 구매하신 제품과 상품은 정품으로 본사 및 전문점에서 A/S를 받을 수 있습니다.
- 무상 A/S기간에 상관없이 밴드교체 및 유리교체 등 소모품성 및 고객님의 부주의로 인한 파손은 유상 A/S(비용청구)로 처리됩니다.
- A/S 처리방법은 매장으로 방문하시거나 전화해 주시고, 우편이나 택배이용시 배송료는 본인 부담입니다.
- A/S 처리기간은 고장상태와 부품조달 관계로 1주일에서 최장 3개월까지 걸릴 수 있습니다.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?